Strumento per ingegneria · ISO 286-1
Calcolatore delle tolleranze.
Calcolate la tolleranza dimensionale di un albero o di un foro secondo ISO 286: scegliete dimensione, posizione e qualità e ottenete le quote massima e minima.
Confrontate
Tabella delle tolleranze: stessa posizione, altre qualità
| Classe | Scostamento superiore | Scostamento inferiore | IT | Quota minima | Quota massima |
|---|---|---|---|---|---|
| H01 | +0,6 µm | 0 µm | 0,6 µm | 25,000 mm | 25,001 mm |
| H0 | +1 µm | 0 µm | 1 µm | 25,000 mm | 25,001 mm |
| H1 | +1,5 µm | 0 µm | 1,5 µm | 25,000 mm | 25,002 mm |
| H2 | +2,5 µm | 0 µm | 2,5 µm | 25,000 mm | 25,003 mm |
| H3 | +4 µm | 0 µm | 4 µm | 25,000 mm | 25,004 mm |
| H4 | +6 µm | 0 µm | 6 µm | 25,000 mm | 25,006 mm |
| H5 | +9 µm | 0 µm | 9 µm | 25,000 mm | 25,009 mm |
| H6 | +13 µm | 0 µm | 13 µm | 25,000 mm | 25,013 mm |
| H7 | +21 µm | 0 µm | 21 µm | 25,000 mm | 25,021 mm |
| H8 | +33 µm | 0 µm | 33 µm | 25,000 mm | 25,033 mm |
| H9 | +52 µm | 0 µm | 52 µm | 25,000 mm | 25,052 mm |
| H10 | +84 µm | 0 µm | 84 µm | 25,000 mm | 25,084 mm |
| H11 | +130 µm | 0 µm | 130 µm | 25,000 mm | 25,130 mm |
| H12 | +210 µm | 0 µm | 210 µm | 25,000 mm | 25,210 mm |
| H13 | +330 µm | 0 µm | 330 µm | 25,000 mm | 25,330 mm |
| H14 | +520 µm | 0 µm | 520 µm | 25,000 mm | 25,520 mm |
| H15 | +840 µm | 0 µm | 840 µm | 25,000 mm | 25,840 mm |
| H16 | +1300 µm | 0 µm | 1300 µm | 25,000 mm | 26,300 mm |
| H17 | +2100 µm | 0 µm | 2100 µm | 25,000 mm | 27,100 mm |
| H18 | +3300 µm | 0 µm | 3300 µm | 25,000 mm | 28,300 mm |
Come si legge una tolleranza ISO: H7, h6, g6
Una quota come Ø25 H7 è composta da tre parti: la dimensione nominale (25 mm), la posizione della zona di tolleranza rispetto alla linea zero (lettera: maiuscola per i fori, minuscola per gli alberi) e la qualità o grado di tolleranza (numero: più è basso, più è precisa).
- H / h sono le posizioni base: il foro H inizia sulla linea zero e cresce verso l'alto; l'albero h inizia sulla linea zero e scende.
- A a G / a a g lasciano gioco (foro maggiore, albero minore). K a ZC / k a zc invadono la linea zero: transizione o interferenza.
- In Proto&Go!, il riferimento per la lavorazione con disegno è IT7 nei metalli e IT11 nelle plastiche tecniche. Il team conferma la fattibilità delle quote richieste controllando il pezzo.
Che qualità richiedere secondo il processo
| Processo Proto&Go! | Riferimento con disegno | Esempio a Ø25 mm |
|---|---|---|
| Lavorazione CNC in metallo | IT7 | H7 → da 25,000 a 25,021 mm |
| Lavorazione CNC in plastica tecnica | IT11 | H11 → da 25,000 a 25,130 mm |
Tabella delle tolleranze ISO 286 per diametro: H7, H8, H11, h6, h7 e g6
Scostamento superiore e inferiore in micron (µm) delle classi più usate: fori in maiuscolo e alberi in minuscolo. Per esempio, Ø25 H7 è +21 / 0 µm. Per un'altra classe o una quota precisa, usa il calcolatore qui sopra.
| Ø (mm) | H7 | H8 | H11 | h6 | h7 | g6 |
|---|---|---|---|---|---|---|
| ≤ 3 | +10 / 0 | +14 / 0 | +60 / 0 | 0 / −6 | 0 / −10 | −2 / −8 |
| 3–6 | +12 / 0 | +18 / 0 | +75 / 0 | 0 / −8 | 0 / −12 | −4 / −12 |
| 6–10 | +15 / 0 | +22 / 0 | +90 / 0 | 0 / −9 | 0 / −15 | −5 / −14 |
| 10–18 | +18 / 0 | +27 / 0 | +110 / 0 | 0 / −11 | 0 / −18 | −6 / −17 |
| 18–30 | +21 / 0 | +33 / 0 | +130 / 0 | 0 / −13 | 0 / −21 | −7 / −20 |
| 30–50 | +25 / 0 | +39 / 0 | +160 / 0 | 0 / −16 | 0 / −25 | −9 / −25 |
| 50–80 | +30 / 0 | +46 / 0 | +190 / 0 | 0 / −19 | 0 / −30 | −10 / −29 |
| 80–120 | +35 / 0 | +54 / 0 | +220 / 0 | 0 / −22 | 0 / −35 | −12 / −34 |
| 120–180 | +40 / 0 | +63 / 0 | +250 / 0 | 0 / −25 | 0 / −40 | −14 / −39 |
| 180–250 | +46 / 0 | +72 / 0 | +290 / 0 | 0 / −29 | 0 / −46 | −15 / −44 |
| 250–315 | +52 / 0 | +81 / 0 | +320 / 0 | 0 / −32 | 0 / −52 | −17 / −49 |
| 315–400 | +57 / 0 | +89 / 0 | +360 / 0 | 0 / −36 | 0 / −57 | −18 / −54 |
| 400–500 | +63 / 0 | +97 / 0 | +400 / 0 | 0 / −40 | 0 / −63 | −20 / −60 |
Ogni riga va da oltre la prima quota fino alla seconda inclusa. Valori secondo ISO 286-1.
Tolleranze dimensionali, generali e geometriche
Questo calcolatore copre le toleranze dimensionali di alberi e fori di ISO 286. Le quote senza tolleranza indicata si reggono dalle toleranze generali ISO 2768 (ad esempio ISO 2768-mK), e quelle di forma e posizione dalle toleranze geometriche di ISO 1101.
Che significato ha H7 in un foro e quali sono le sue misure limite?
H7 definisce la tolleranza dimensionale di un foro. La lettera H fissa la scostamento inferiore a zero: la misura minima coincide con la nominale. Il grado 7 determina l'ampiezza della tolleranza in base al diametro. Per esempio, un foro Ø25 H7 ammette misure tra 25,000 e 25,021 mm.
Qual è la differenza tra H7 per un foro e h6 per un albero?
Le maiuscole identificano le tolleranze dei fori e le minuscole, degli alberi. In H7, il foro può essere uguale o maggiore della dimensione nominale; in h6, l'albero può essere uguale o minore. Per lo stesso diametro nominale, la combinazione H7/h6 ha un gioco minimo di zero. I gradi 7 e 6 determinano l'ampiezza di ciascuna tolleranza.
Come calcolo le misure massima e minima di un albero o foro secondo ISO 286?
Nel calcolatore delle tolleranze di Proto&Go!, scegliete albero o foro e inserite la dimensione nominale, la posizione e il grado di tolleranza. Otterrete le misure massima e minima in millimetri e gli scostamenti in micron. La tabella permette di confrontare i gradi disponibili per quella posizione. Lo strumento copre le dimensioni nominali maggiori di zero fino a 500 mm.